Технические характеристики
| Type: | HDA4-54 | Rated voltage (kV): | 54 |
| MCOV (kV): | 42 | Max 0.5μs discharge woltage (kV)1: | 135 |
| Max switchingsurge protective level At classifying current levels (kV)2: | 100 | Max discharge voltage using an 8/20 current wave (kV): | 107 |
| Type: | HDA4-60 | Rated voltage (kV): | 60 |
| MCOV (kV): | 48 | Max 0.5μs discharge woltage (kV)1: | 150 |
| Max switchingsurge protective level At classifying current levels (kV)2: | 111 | Max discharge voltage using an 8/20 current wave (kV): | 119 |
| Type: | HDA4-72 | Rated voltage (kV): | 72 |
| MCOV (kV): | 57 | Max 0.5μs discharge woltage (kV)1: | 178 |
| Max switchingsurge protective level At classifying current levels (kV)2: | 132 | Max discharge voltage using an 8/20 current wave (kV): | 141 |
| Type: | HDA4-90 | Rated voltage (kV): | 90 |
| MCOV (kV): | 70 | Max 0.5μs discharge woltage (kV)1: | 225 |
| Max switchingsurge protective level At classifying current levels (kV)2: | 166 | Max discharge voltage using an 8/20 current wave (kV): | 178 |
| MCOV (kV): | 74 | Max 0.5μs discharge woltage (kV)1: | 238 |
| Max switchingsurge protective level At classifying current levels (kV)2: | 176 | Max discharge voltage using an 8/20 current wave (kV): | 188 |
| Type: | HDA4-96 | Rated voltage (kV): | 96 |
| MCOV (kV): | 76 | Type: | HDA4-108 |
| Rated voltage (kV): | 108 | MCOV (kV): | 84 |
| Max 0.5μs discharge woltage (kV)1: | 269 | Max switchingsurge protective level At classifying current levels (kV)2: | 199 |
| Max discharge voltage using an 8/20 current wave (kV): | 213 | MCOV (kV): | 88 |
| Max 0.5μs discharge woltage (kV)1: | 275 | Max switchingsurge protective level At classifying current levels (kV)2: | 203 |
| Max discharge voltage using an 8/20 current wave (kV): | 218 | Type: | HDA4-120 |
| Rated voltage (kV): | 120 | MCOV (kV): | 98 |
| Max 0.5μs discharge woltage (kV)1: | 306 | Max switchingsurge protective level At classifying current levels (kV)2: | 235 |
| Max discharge voltage using an 8/20 current wave (kV): | 242 | Type: | HDA4-132 |
| Rated voltage (kV): | 132 | MCOV (kV): | 106 |
| Max 0.5μs discharge woltage (kV)1: | 332 | Max switchingsurge protective level At classifying current levels (kV)2: | 254 |
| Max discharge voltage using an 8/20 current wave (kV): | 263 | Type: | HDA4-144 |
| Rated voltage (kV): | 144 | MCOV (kV): | 115 |
| Max 0.5μs discharge woltage (kV)1: | 360 | Max switchingsurge protective level At classifying current levels (kV)2: | 276 |
| Max discharge voltage using an 8/20 current wave (kV): | 285 | Type: | HDA4-168 |
| Rated voltage (kV): | 168 | MCOV (kV): | 131 |
| Max 0.5μs discharge woltage (kV)1: | 416 | Max switchingsurge protective level At classifying current levels (kV)2: | 319 |
| Max discharge voltage using an 8/20 current wave (kV): | 330 | Type: | HDA4-172 |
| Rated voltage (kV): | 172 | MCOV (kV): | 140 |
| Max 0.5μs discharge woltage (kV)1: | 438 | Max switchingsurge protective level At classifying current levels (kV)2: | 336 |
| Max discharge voltage using an 8/20 current wave (kV): | 347 | Type: | HDA4-180 |
| Rated voltage (kV): | 180 | MCOV (kV): | 144 |
| Max 0.5μs discharge woltage (kV)1: | 450 | Max switchingsurge protective level At classifying current levels (kV)2: | 345 |
| Max discharge voltage using an 8/20 current wave (kV): | 357 | Type: | HDA4-192 |
| Rated voltage (kV): | 192 | MCOV (kV): | 152 |
| Max 0.5μs discharge woltage (kV)1: | 478 | Max switchingsurge protective level At classifying current levels (kV)2: | 365 |
| Max discharge voltage using an 8/20 current wave (kV): | 377 | Type: | HDA4-228 |
| Rated voltage (kV): | 228 | MCOV (kV): | 180 |
| Max 0.5μs discharge woltage (kV)1: | 568 | Max switchingsurge protective level At classifying current levels (kV)2: | 436 |
| Max discharge voltage using an 8/20 current wave (kV): | 450 | Type: | HDA4-258 |
| Rated voltage (kV): | 258 | MCOV (kV): | 209 |
| Max 0.5μs discharge woltage (kV)1: | 659 | Max switchingsurge protective level At classifying current levels (kV)2: | 526 |
| Max discharge voltage using an 8/20 current wave (kV): | 522 |
Описание продукта
Задержка перенапряжения типа станции (серия HDA4) Задержка перенапряжения станции разработана с высокой точностью для обеспечения надежной защиты критического электрического оборудования на электростанциях.Он обладает превосходными нелинейными свойствами и быстрым временем реагирования на крутые вол...
Задержка перенапряжения типа станции (серия HDA4)
Задержка перенапряжения станции разработана с высокой точностью для обеспечения надежной защиты критического электрического оборудования на электростанциях.Он обладает превосходными нелинейными свойствами и быстрым временем реагирования на крутые волны..
Ключевые преимущества:
- ✅Отличные нелинейные свойства:Обеспечивает стабильную работу при различных электрических нагрузках.
- ✅Мощность высокого тока:Надежная защита от высокоэнергетических разрядов.
- ✅Высокая способность к борьбе со старением:Разработан для долгосрочной долговечности в сложных условиях.
- ✅Не требует обслуживания:Оптимизированный дизайн для легкой установки и сокращения времени простоя.
Технические спецификации
Сообщение для быстрого ответа