Specifications
No.: 1 Description: Rated Voltage
Unit: KV Parameter: 12 / 24
No.: 2 Description: Rated Current
Unit: A Parameter: 630-4000 / 630-3150
No.: 3 Description: Rated Frequency
Unit: Hz Parameter: 50
No.: 4 Description: Rated Busbar Current
No.: 5 Description: Power Frequency Withstand Voltage (1min) - Phase To Phase/earth
Parameter: 42 / 65 Description: Power Frequency Withstand Voltage (1min) - Across The Isolating Distance
Parameter: 48 / 79 No.: 6
Description: Lightning Impulse Withstand Voltage - Phase To Phase/earth Parameter: 75 / 125
Description: Lightning Impulse Withstand Voltage - Across The Isolating Distance Parameter: 85 / 145
No.: 7 Description: Rated Short Circuit Breaking Current
Unit: KA Parameter: 25, 31.5, 40
No.: 8 Description: Rated Short Circuit Making Current (peak)
Parameter: 63, 80, 100 No.: 9
Description: Rated Peak Withstand Current No.: 10
Description: Rated Short Time Withstand Current No.: 11
Description: During Of Short Circuit Unit: S
Parameter: 4 / 25, 31.5, 40 No.: 12
Description: Protection Degree Parameter: Enclosure IP4X; Partition Between Compartments IP2X
Product Description
ZW32-24 Series Outdoor High Voltage Vacuum Breaker The ZW32-24 series is a high-performance outdoor vacuum circuit breaker designed for 24kV three-phase AC 50Hz power systems. Engineered for reliability, it excels in closing and breaking load currents, overcurrents, and short-circuit currents. Key ...

ZW32-24 Series Outdoor High Voltage Vacuum Breaker

The ZW32-24 series is a high-performance outdoor vacuum circuit breaker designed for 24kV three-phase AC 50Hz power systems. Engineered for reliability, it excels in closing and breaking load currents, overcurrents, and short-circuit currents.

Key Advantages

  • Smart Control: Equipped with reclosing controllers to identify fault characteristics and automate isolation.
  • Integrated Power: Self-provided PT acts as a power source, enabling signal output for voltage and current monitoring.
  • Advanced Protection: Supports three-stage composite protection including overcurrent delay, inrush current delay, and quick-break.

Product Attributes

Application
Outdoor Power Systems
Protection Level
Enclosure IP4X; Partition IP2X
Frequency
50 Hz

Technical Specifications

No. Description Unit Parameter
1Rated voltagekV12 / 24
2Rated currentA630-4000 / 630-3150
3Rated frequencyHz50
4Rated busbar currentA630-4000 / 630-3150
5Power frequency withstand (Ph-Ph/Earth)kV42 / 65
6Lightning impulse withstand (Ph-Ph/Earth)kV75 / 125
7Rated short circuit breaking currentkA25, 31.5, 40
8Rated short circuit making current (peak)kA63, 80, 100